MONSTART=NO_DETECT_THE_MONIT, MONNACK=ACKNOWLEDGED_THE_DA, MONRESTART=NO_START_DETECT_THE
Monitor receiver data register.
MONRXDAT | Monitor function Receiver Data. This reflects every data byte that passes on the I2C pins, and adds indication of Start, Repeated Start, and data Nack. |
MONSTART | Monitor Received Start. 0 (NO_DETECT_THE_MONIT): No detect. The monitor function has not detected a Start event on the I2C bus. 1 (START_DETECT_THE_MO): Start detect. The monitor function has detected a Start event on the I2C bus. |
MONRESTART | Monitor Received Repeated Start. 0 (NO_START_DETECT_THE): No start detect. The monitor function has not detected a Repeated Start event on the I2C bus. 1 (REPEATED_START_DETEC): Repeated start detect. The monitor function has detected a Repeated Start event on the I 2C bus. |
MONNACK | Monitor Received Nack. 0 (ACKNOWLEDGED_THE_DA): Acknowledged. The data currently being provided by the monitor function was acknowledged by at least one master or slave receiver. 1 (NOT_ACKNOWLEDGED_TH): Not acknowledged. The data currently being provided by the monitor function was not acknowledged by any receiver. |
RESERVED | Reserved. Read value is undefined, only zero should be written. |