NXP Semiconductors /LPC800 /I2C /MONRXDAT

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as MONRXDAT

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0MONRXDAT0 (NO_DETECT_THE_MONIT)MONSTART 0 (NO_START_DETECT_THE)MONRESTART 0 (ACKNOWLEDGED_THE_DA)MONNACK 0RESERVED

MONSTART=NO_DETECT_THE_MONIT, MONNACK=ACKNOWLEDGED_THE_DA, MONRESTART=NO_START_DETECT_THE

Description

Monitor receiver data register.

Fields

MONRXDAT

Monitor function Receiver Data. This reflects every data byte that passes on the I2C pins, and adds indication of Start, Repeated Start, and data Nack.

MONSTART

Monitor Received Start.

0 (NO_DETECT_THE_MONIT): No detect. The monitor function has not detected a Start event on the I2C bus.

1 (START_DETECT_THE_MO): Start detect. The monitor function has detected a Start event on the I2C bus.

MONRESTART

Monitor Received Repeated Start.

0 (NO_START_DETECT_THE): No start detect. The monitor function has not detected a Repeated Start event on the I2C bus.

1 (REPEATED_START_DETEC): Repeated start detect. The monitor function has detected a Repeated Start event on the I 2C bus.

MONNACK

Monitor Received Nack.

0 (ACKNOWLEDGED_THE_DA): Acknowledged. The data currently being provided by the monitor function was acknowledged by at least one master or slave receiver.

1 (NOT_ACKNOWLEDGED_TH): Not acknowledged. The data currently being provided by the monitor function was not acknowledged by any receiver.

RESERVED

Reserved. Read value is undefined, only zero should be written.